For determining the presence, position, direction, depth and diameter of steel reinforcement bars in concrete structures.
STANDARDS: BS 1881:204 | DIN 1045
C403-01
PROFOSCOPE
Versatile, fully-integrated rebar detector and cover meter with a
unique real-time rebar display allowing the user to actually SEE the
location of the rebar beneath the concrete surface to a maximum
deep of 180 mm.
This is coupled with rebar-proximity indicators and optical and
acoustical locating aids. Rebar diameter can also be estimated
within the specified testing range.
The Profoscope combines these unique features in a compact,
light device that allows the user to operate this rebar detector with
one hand making the task of locating rebars a simple and efficient
process.
An intuitive user interface makes rebar detection easy.
MAIN FEATURES
Visual indication of rebars in close proximity.
Ability to identify the mid-point between rebars as
well as the orientation of rebars.
Optical and acoustical indication of rebar location
and minimum cover alert.
Neighboring bar correction.
Cordless and single handed operation.
Icon-based language independent menus.
Start-up test kit allows user to familiarize with all
functions in a comfortable environment, wasting no
time on site.
C403-02
PROFOSCOPE+ (PLUS)
Same features of mod. C403-01, but additionally offers the innovative
memory function for automatic data acquisition, by eliminating
the manual measurements of a test series, saving time and unnecessary
source of errors.
C396N
PROFOMETER PM-600
This new generation Profometer Touchscreen unit offers real
time control over the measurement procedure for the precise and
non-destructive detection of rebar locations and measurement of
the concrete cover and rebar diameters directly on site.
The instrument comes along with the Universal Probe with integrated
spot probe for measurements in corners, limited spaces and
congested rebar arrangements.
Deep measuring range: up to 175 mm
Measurement accuracy: from ± 1 to ± 4 mm
Screen: 7” color, 800×480 pixel.
Diameter accuracy measurement: ± 1 mm
Diameter measuring range: up to 63 mm
Weight: 1600 g
Note: Possibility to upgrade the Profometer C396N to Profometer
Corrosion C411N for both corrosion and cover meter
functions with the KIT below:
C411-01N
UPGRADE KIT TO PROFOMETER CORROSION C411N
Interface box, rod electrode, cable coil l=25 m with clamp, DVD
with software, documentation and carrying case.
Technical details: see C411N.
C411N
PROFOMETER CORROSION
STANDARDS: ASTM C876, RILEM TC 154-EMC, DGZFP B3,
SIA 2006, UNI 10174, JGJ/T 152, JSCE E 601
This instrument is the direct successor to the Canin and it is the
most advanced corrosion detection device in the market. Consists
in a non-destructive method to determine the corrosion of the
reinforcement bars.
Same as C396N model, but with the accessories to detect corrosion
and without the accessories to measure concrete cover and rebar
location.
Supplied complete with rod electrode.
Memory: internal 8 GB flash memory
Regional settings: metric and imperial units and multi-language
and timezone supported
Power input: 12 V ± 25 % / 1.5 A
Battery: 3.6 V, 14 Ah
Battery lifetime: > 8h (in standard operating mode)
Humidity: < 95 % RH, non condensing
Operating temperature: -10 °C to +50 °C
IP classification: touchscreen IP54, universal probe IP67
Voltage measuring range: -1000 to + 1000 mV
Voltage resolution: 1 mV
Impedance: 100 MΩ
Sampling rate: 900 Hz
Dimensions: 250x162x62 mm
Weight: 1600 g approx.
Note: Possibility to upgrade the Profometer Corrosion C411N
to Profometer PM-600 C396N for both corrosion and
cover meter functions with the KIT below.
C396-01N
UPGRADE KIT TO PROFOMETER CORROSION
Universal probe with ruggedized cart, probe cable 1.5 m, software
upgrade to cover meter.
Technical details: see C396N.
C412-01
DIGITAL RESISTIVITY 2-PROBE ARRAY METER
Used for assessing the probable rate of corrosion in reinforcing bars
with the electric resistivity measurement method.
A highly permeable concrete has a high conductivity with reduced
electrical resistance. The knowledge of the electrical resistance of
a concrete allows to measure the possible rate of corrosion of steel
reinforced bars.
The test is simple to perform and requires only two 6.5 mm
diameter holes drilled to a depth of 8 mm. Inject a small amount of
conductive gel into each hole and insert the probes. The resistivity
value is immediately displayed.
– Measuring range: 0.5 to 20 kΩ cm, with 0.1 kΩ resolution.
– 2-probe array spacing: 5 cm
– Display: LCD 4 ¼ digit
– Battery operated with 100 hours operating time
The instrument is supplied complete with drill bit, gel, template,
accessories, carrying case.
Dimensions: 400x270x130 mm
Total weight: 4 kg
C414
COR MAP-HALF CELL METHOD
STANDARDS: ASTM C876 | BS 1881:201 | UNI 9535
A simple method for identifying areas of probable rebar corrosion in
concrete structures.
Detachable electrode extension pieces (41 cm long), facilitate
measurements in hard to reach locations.
High impedance digital meter is designed for tough field conditions.
Reference electrode, including copper sulphate reservoir.
Easy to use, supplied complete.