Menu Close

A124 FILLER COMPACTION APPARATUS

Categories: ,

DETERMINATION OF THE VOIDS CONTENT OF DRY
COMPACTED FILLER.
STANDARDS: EN 1097-4 comparable to BS 812 | CNR N° 123
NLT 177
The apparatus consists of:
cylinder with an inside diameter of 25.4 mm; plunger freely sliding
into the cylinder with max. lateral play of 0.20 ± 0.05 mm; four
columns and metallic base holding the whole.
To perform the test a measuring device (vernier caliper with 0.01 mm
accuracy) is required: see accessory.
Weight: 4 kg approx.

ACCESSORIES
A124-01 FILTER PAPER Ø 25 mm (pack of 100).
V175-03 DIGITAL VERNIER CALIPER 0 – 150 mm x 0.01 mm sens.